Print Back
  • LED display
  • Can be used with other digital optical encoders
  • Consists of multiple output interfaces
  • Suitable for cutting and wood-processing machines
  • Compact design and easy installation
High Effciency Single Axis Counter
Unit of Measure
Items High Effciency Single Axis Counter
PMED-H1-1-00-0
High Effciency Single Axis Counters
High Effciency Single Axis Counter
PMED-H1-1-00-1
High Effciency Single Axis Counters
High Effciency Single Axis Counter
PMED-H1-1-00-2
High Effciency Single Axis Counters
High Effciency Single Axis Counter
PMED-H1-1-00-3
High Effciency Single Axis Counters
High Effciency Single Axis Counter
PMED-H1-1-A1-0
High Effciency Single Axis Counters
H1 Display N/A Plug type A,flat blade
Number of Axis N/A 1
Use with N/A HIWIN 1mm positioning measurement system (analogue/digital) N/A HIWIN 1mm positioning measurement system (analogue/digital) N/A HIWIN 1mm positioning measurement system (analogue/digital) N/A HIWIN 1mm positioning measurement system (analogue/digital) N/A HIWIN 5mm E type or H type positioning measurement system
Display N/A LED display
Resolution N/A 1 µm2 µm5 µm10 µm
Input Signal N/A Analogue: SIN/COS 1 Vp-p; speed 2 m/s Digital: 5 V TTL/RS422; speed 2 m/s N/A Analogue: SIN/COS 1 Vp-p; speed 2 m/s Digital: 5 V TTL/RS422; speed 2 m/s N/A Analogue: SIN/COS 1 Vp-p; speed 2 m/s Digital: 5 V TTL/RS422; speed 2 m/s N/A Analogue: SIN/COS 1 Vp-p; speed 2 m/s Digital: 5 V TTL/RS422; speed 2 m/s N/A Analogue: SIN/COS 1 Vp-p; speed 2 m/s
Input Voltage N/A 5 VDC±5% 1A (AC100-240V/5 VDC)
Relay Contact Rating N/A 24 VDC/2 A
Operating Temperature [Min] N/A 0 ºC
Operating Temperature [Max] N/A 50 ºC
Storage Temperature [Min] N/A -5 ºC
Storage Temperature [Max] N/A 70 ºC
Protection Class Display N/A IP43
Function General N/A Absolute/Incremental position(INC/ABS) selection Coordinate zero setting and auto-center (1/2) function Input signal conversion (Digital/Analogue) Set display digits(mm:0.001, 0.01, 0.1, inch:0.000001, 0.00001, 0.0001, 0.001) Set reading direction Unit conversion (mm/inch)
Function Other N/A 4 sets of relay output function 8 sets of preset function Instant power failure memory with I/0 without RS-232 N/A 4 sets of relay output function 8 sets of preset function Instant power failure memory with I/0 with RS-232 N/A 4 sets of relay output function 8 sets of preset function Instant power failure memory without I/0 without RS-232 (Standard) N/A 4 sets of relay output function 8 sets of preset function Instant power failure memory without I/0 with RS-232 N/A 4 sets of relay output function 8 sets of preset function Instant power failure memory with I/0 without RS-232
Number of Digits N/A 8
Signal Format N/A Analogue Digital N/A Analogue Digital N/A Analogue Digital N/A Analogue Digital N/A Analogue
Operating Frequency N/A 2 MHz0.5 kHz N/A 2 MHz0.5 kHz N/A 2 MHz0.5 kHz N/A 2 MHz0.5 kHz N/A 2 MHz